Media 000409514: Coronoid [Mesh] [CT]
Represents:
Biological Specimen
In Collection

GENERAL DETAILS

Media ID
000409514
Media type
Mesh
Object element or part
Coronoid
Side
Left
Orientation
--
Short description
--
Full description
--
Creator
Jasper Ponstein
Date created
December 22, 2021
Date uploaded
December 22, 2021

FILE OBJECT DETAILS

File format(s)
application/ply
File size
1.19 MB
Points
16,970
Polygons
34,414
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
5.020, 10.693, 6.604
Centroid coordinates
417.330, 669.257, -721.596
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s, UChicago PaleoCT (University of Chicago)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
IP holder
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object fmnh:amphibians and reptiles:216746 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s
Device facility
UChicago PaleoCT (University of Chicago)
Creator
April Isch Neander
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
0.5
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
2
Projections
1800
Voltage
80
Power
--
Amperage
200
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000077406: Element Unspecified [CTImageSeries] [Etc] .

Processing Details

Creator
April Isch Neander
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000077406: Element Unspecified [CTImageSeries] [Etc] was processed to create derived Media 000409514: Coronoid [Mesh] [CT] (this media).

Processing Details

Creator
Jasper Ponstein
Date processed
--
Software
VGStudio
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000409514: Coronoid [Mesh] [CT] (this media)