Media 000411951: Hamate [Mesh] [CT]
Represents:
Biological Specimen
In Collection

1 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

GENERAL DETAILS

Media ID
000411951
Media type
Mesh
Object element or part
Hamate
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Olivia Di Iorio
Date created
November 19, 2021
Date uploaded
January 09, 2022

FILE OBJECT DETAILS

File format(s)
application/stl
File size
33.8 MB
Points
66,112
Polygons
132,220
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
9.408, 8.729, 8.387
Centroid coordinates
5.915, 4.814, 4.765
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (2 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object dlc:6804m was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Gabriel Yapuncich
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
0.354
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
2
Projections
2000
Voltage
165
Power
--
Amperage
170
Surrounding material
air
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000170487: Hands [CTImageSeries] [CT] .

Processing Details

Creator
Gabriel Yapuncich
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000170487: Hands [CTImageSeries] [CT] was processed with 2 activities to create derived Media 000411951: Hamate [Mesh] [CT] (this media).

Processing Details

Creator
Olivia Di Iorio
Date processed
November 19, 2021
Software
Geomagic
Description
--
Description attachment
None

Processing Activity 1: Smoothing/Noise Reduction

Software
Avizo
Description

Processing Activity 2: Reconstructed Tomography to Mesh

Software
Geomagic
Description

Media produced by this event on MorphoSource


Media 000411951: Hamate [Mesh] [CT] (this media)