Media 000434572: Sclerotic Rings
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

GENERAL DETAILS Field Definitions

Media ID
000434572
Media type
Mesh
Object element or part
Sclerotic rings
Object represented
Object taxonomy
Pezoporus occidentalis
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Alice Clement
Date created
April 11, 2022
Date uploaded
April 11, 2022

FILE OBJECT DETAILS Field Definitions

File name
NightParrot-whole_56um_Sclerotic-rings.stl
File format(s)
STL
File size
1.72 MB
Points
17719
Polygons
36110
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
18.117, 9.849, 11.046
Centroid coordinates
19.055, 13.857, 23.624
Units of point coordinates
Um

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (2 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, NHMUK Imaging and Analysis Centre (The Natural History Museum, London)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
The Trustees of the Natural History Museum, London
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
These data first appeared in Shute, Clement & Prideaux (2023) EMU - AUSTRAL ORNITHOLOGY https://doi.org/10.1080/01584197.2023.2181185
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object nhmuk:pal:1868.1.27.30 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
NHMUK Imaging and Analysis Centre (The Natural History Museum, London)
Creator
Vincent Fernandez
Event date
--
Software
Nikon Metrology Inspect X 6.2
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
--
Projections
2254
Voltage
120 kV
Power
--
Amperage
833 µA
Surrounding material
--
X-ray tube type
Nikon 225 Ultrafocus
Target type
--
Detector type
Scintillator (Phosphor used)
Detector pixels X
2850
Detector pixels size X
0.15
Detector pixels Y
2850
Detector pixels size Y
0.15
Detector configuration
Area (single or tiled detector)
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
No
Acquisition type
Sequenced

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed with 1 activity to create derived private media that exists on MorphoSource but is inaccessible with current user permissions.

Processing Details Field Definitions

Creator
Vincent Fernandez
Event date
--
Software
Nikon Metrology CT Pro 3D
Description
Tomographic reconstruction
Description attachment
None

Processing Activity 1: Reconstruction

Software
Nikon Metrology CT Pro 3D
Description
Tomographic reconstruction

Media produced by this event on MorphoSource

Private media inaccessible with current permissions

STEP 3: IMAGE PROCESSING

Derived private media was processed with 1 activity to create derived Media 000434572: Sclerotic Rings [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Alice Clement
Event date
--
Software
Mimics
Description
--
Description attachment
None

Processing Activity 1: Reconstructed Tomography to Mesh

Software
Description

Media produced by this event on MorphoSource

Media 000434572: Sclerotic Rings [Mesh] [CT] (this media)