Media 000436197: Head [CTImageSeries] [CT]
Represents:
Biological Specimen

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

GENERAL DETAILS

Media ID
000436197
Media type
CTImageSeries
Object element or part
head
Side
--
Orientation
--
Short description
Common seadragon head
Full description
Common seadragon Xradia scan of head.
Creator
--
Date created
--
Date uploaded
April 25, 2022

FILE OBJECT DETAILS

File format(s)
image/tiff
File size
14.1 GB
Image width
4763
Image height
5969
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
18.000000
Y pixel spacing
17.000000
Z pixel spacing
18.000000
Pixel spacing units
Um
Slice thickness
--
Number of images in set
4,171

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia 620, Knight Campus X-ray Imaging Core Facility (University of Oregon)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
PNAS
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UO:PTA:01 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia 620
Device facility
Knight Campus X-ray Imaging Core Facility (University of Oregon)
Creator
--
Date
--
Software
Dragonfly
Description
1 single normal-field, 1 vertical-stitch normal-field scan of 3 segments; energy 80kV, power 10W, Objective 0.4X, Binning 1
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
80kV
Power
10W
Amperage
--
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000436197: Head [CTImageSeries] [CT] (this media).

Processing Details

Creator
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000436197: Head [CTImageSeries] [CT] (this media)