Media 000446755: Whole Specimen (No Tail)
Restricted Download
Type CT Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

TAGS

No tags found.

GENERAL DETAILS

Media ID
000446755
Media type
CT Image Series
Object element or part
Whole specimen (no tail)
Object represented
Object taxonomy
Matobosaurus maltzahni
Object organization
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Edward Stanley
Date created
--
Date uploaded
June 17, 2022

FILE OBJECT DETAILS

File format(s)
image/tiff
File size
1.01 GB
Image width
943
Image height
592
Color space
BlackIsZero
Color depth
16
Compression
PackBits
Series type
Reconstructed image stack
X pixel spacing
0.078278
Y pixel spacing
0.078278
Z pixel spacing
0.078278
Pixel spacing units
Mm
Slice thickness
0.07827777
Number of images in set
3,481

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS

Data uploaded by
Publication status
Restricted Download
IP holder
California Academy of Sciences
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object CAS:HERP:263016 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Date
--
Software
Datos X|A
Description
MicroCT of CAS-H-263016 full specimen
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
0.200098
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
3
Projections
1200
Voltage
100kV
Power
25W
Amperage
250uA
Surrounding material
air
Xray tube type
--
Target type
Reflection
Detector type
Scintillator (Phosphor used)
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
Tungston (W)
Rotation number
--
Phase contrast
No
Optical magnification
No
Acquisition type
Sequenced

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000446755: Whole Specimen (No Tail) [CTImageSeries] [CT] (this media).

Processing Details

Creator
Edward Stanley
Date processed
--
Software
Datos X|r
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000446755: Whole Specimen (No Tail) [CTImageSeries] [CT] (this media)