Media 000448260: Dicect Whole Body [CTImageSeries] [CT]
Represents:
Biological Specimen

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

GENERAL DETAILS

Media ID
000448260
Media type
CTImageSeries
Object element or part
dicect-whole-body
Side
--
Orientation
--
Short description
Stained with 1.25% buffered-Lugol's iodine
Full description
--
Creator
Jaimi Gray
Date created
April 27, 2022
Date uploaded
June 29, 2022

FILE OBJECT DETAILS

File format(s)
image/tiff
File size
3.73 GB
Image width
1366
Image height
1317
Color space
BlackIsZero
Color depth
16
Compression
PackBits
Series type
Reconstructed image stack
X pixel spacing
0.021886
Y pixel spacing
0.021886
Z pixel spacing
0.021886
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
7,173

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF DBI-1701714 ("oVert: TCN" parent grant)
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object vims:vims:915 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Jaimi Gray
Date
April 27, 2022
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
Al 0.3 mm
Exposure time
200 ms
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
3
Projections
2200
Voltage
100 kV
Power
200 uA
Amperage
--
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000448260: Dicect Whole Body [CTImageSeries] [CT] (this media).

Processing Details

Creator
Jaimi Gray
Date processed
April 27, 2022
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000448260: Dicect Whole Body [CTImageSeries] [CT] (this media)