Media 000459259: Skull
Open Download
Type Video
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

No collections found.

GENERAL DETAILS Field Definitions

Media ID
000459259
Media type
Video
Object element or part
Skull
Object represented
Object taxonomy
Rafetus bohemicus
Object organization
Side
NotApplicable
Orientation
--
Short description
Skull of Rafetus bohemicus
Full description
3D video of the skull of Rafetus bohemicus
Creator
Michal Vopálenský
Date created
June 24, 2020
Date uploaded
September 04, 2022

FILE OBJECT DETAILS Field Definitions

File name
Peerj-73966-Zelva-Video.mp4
File format(s)
MP4
File size
4.36 MB

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
CET Custom built Dual Source microCT, Laboratory of X-Ray Tomography in the Institute of Theoretical and Applied Mechanics, Centre of Excellence Telč (Czech Academy of Sciences)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
Milan Chroust
Copyright statement
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
GAUK N. 1094119
Publisher
Institute of Theoretical and Applied Mechanicsof the Czech Academy of Sciences
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object NMP:Pv:11668 was imaged to create raw Media 000469442: Skull [CTImageSeries] [CT].

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
CET Custom built Dual Source microCT
Device facility
Laboratory of X-Ray Tomography in the Institute of Theoretical and Applied Mechanics, Centre of Excellence Telč (Czech Academy of Sciences)
Creator
Michal Vopálenský
Event date
June 24, 2020
Software
VG Studio Max 3.2
Description
Skull of fossil turtle Rafetus bohemicus
Description attachment
None
Reference attachment
None
Exposure time
1500 ms
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
200
Projections
2400
Voltage
230 kV
Power
57.5 W
Amperage
250 mAs
Surrounding material
claystone
X-ray tube type
XWT 160 TCHR; XWT 240 SE
Target type
--
Detector type
Direct (X-Ray photoconductor)
Detector pixels X
--
Detector pixels size X
200.000
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
Area (single or tiled detector)
Source object distance
369.3 mm
Source detector distance
1231 mm
Target material
skull
Rotation number
--
Phase contrast
--
Optical magnification
Yes
Acquisition type
Free

Media produced by this event on MorphoSource

STEP 2: IMAGE PROCESSING

Raw Media 000469442: Skull [CTImageSeries] [CT] was processed to create derived Media 000459259: Skull [Video] [CT] (this media).

Processing Details Field Definitions

Creator
Michal Vopálenský
Event date
June 24, 2020
Software
VG Studio Max 3.2
Description
created 3D animation of CT Image Series
Description attachment
None

Media produced by this event on MorphoSource

Media 000459259: Skull [Video] [CT] (this media)