Media 000476899: Skull
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000476899
Media type
Volumetric Image Series
Object element or part
Skull
Object represented
Object taxonomy
Felis catus domestica
Side
--
Orientation
--
Short description
domestic cat skull
Full description
CT scan of a domestic cat skull
Creator
Callie Crawford
Date created
May 09, 2016
Date uploaded
October 24, 2022

FILE OBJECT DETAILS Field Definitions

File name
Crawford_cat_fused.zip
File format(s)
ZIP archive, TIFF
File size
6.36 GB
Image width
2000
Image height
2000
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.042239
Y pixel spacing
0.042239
Z pixel spacing
0.042239
Pixel spacing units
Um
Slice thickness
--
Number of images in set
2,667

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (1 step)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
Callie Crawford
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object L-CC:mamm:0001 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Callie Crawford
Event date
May 09, 2016
Software
--
Description
CT scan
Description attachment
None
Reference attachment
None
Exposure time
354
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
0
Projections
2000
Voltage
165
Power
15.84
Amperage
96
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
2000
Detector pixels size X
0.2
Detector pixels Y
2000
Detector pixels size Y
0.2
Detector configuration
--
Source object distance
162.98
Source detector distance
771.73
Target material
--
Rotation number
--
Phase contrast
No
Optical magnification
No
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed with 1 activity to create derived Media 000476899: Skull [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Callie Crawford
Event date
May 09, 2016
Software
--
Description
--
Description attachment
None

Processing Activity 1: Align Parts

Software
ImageJ
Description
merged two scan sections

Media produced by this event on MorphoSource

Media 000476899: Skull [CTImageSeries] [CT] (this media)