Media 000515722: Sacral Vertebra 2 Centrum
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000515722: Sacral Vertebra 2 Centrum
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
Media preview currently unavailable. Please check back later.
In Collections
Project
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000515722
Media type
Volumetric Image Series
Object element or part
sacral vertebra 2 centrum
Object represented
Object taxonomy
Suchomimus tenerensis
Object organization
Side
--
Orientation
--
Short description
zipped dicom stack
Full description
CT scan of Suchomimus tenerensis holotype sacral vertebra 2; original dicom series cropped to just this bone
Creator
Baumgart, Stephanie
Date created
April 17, 2023
Date uploaded
April 17, 2023
FILE OBJECT DETAILS Field Definitions
File name
MNBH_GAD500_sacral_2_centrum.zip
File format(s)
ZIP archive, ZIP archive
File size
31.7 MB
Image width
--
Image height
--
Color space
--
Color depth
--
Compression
--
X pixel spacing
0.651000
Y pixel spacing
0.651000
Z pixel spacing
0.335000
Pixel spacing units
Millimeters
Slice thickness
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Philips Brilliance iCT, Department of Radiology (University of Chicago Medicine)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Sereno lab
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
The data was collected in collaboration with Nicholas Gruszauskas and David Klein at the UChicago Hospital. Paul Sereno provided access to these data, which first appears in Myhrvold et al. 2024: https://doi.org/10.1371/journal.pone.0298957. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
MNBH:GAD:500
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
Department of Radiology (University of Chicago Medicine)
Creator
Klein, David; Gruszauskas, Nicholas
Event date
September 24, 2013
Software
--
Description
--
Description Attachment
None
Photographic Reference
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000515722: Sacral Vertebra 2 Centrum [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
Baumgart, Stephanie
Event date
April 17, 2023
Software
--
Description
cropped original dicom series to specific bone
Description attachment
None