Media 000515752: Quadrate
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000515752
Media type
Volumetric Image Series
Object element or part
quadrate
Object represented
Object taxonomy
Majungasaurus crenatissimus
Side
Right
Orientation
--
Short description
right quadrate
Full description
right quadrate
Creator
Groenke, Joseph
Date created
March 31, 2023
Date uploaded
April 17, 2023

FILE OBJECT DETAILS Field Definitions

File name
UA_8709_r_quadrate.zip
File format(s)
ZIP archive, DICOM
File size
3.1 MB
Image width
512
Image height
512
Color space
--
Color depth
16
Compression
--
Series type
Reconstructed image stack
X pixel spacing
0.248047
Y pixel spacing
0.248047
Z pixel spacing
0.200000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
457

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric LightSpeed VCT 64-slice CT, Stony Brook University Medical Center (Stony Brook University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
O'Connor, Patrick
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Prohibited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF EAR_1123642; NSF EAR_9418816; NSF DBI_2242717; Ohio University Heritage College of Osteopathic Medicine; NSF EAR_1525915
Publisher
Mahajanga Basin Project; O'Connor, Patrick
Cite as
Patrick M. O'Connor and colleagues provided access to these data originally published in SVP Memoir 8 (2007, Vol. 27, Suppl. 2) with data collection and processing funded by the US NSF EAR_9418816, NSF EAR_1123642, NSF EAR_1525915, NSF DBI_2242717 and Ohio University Heritage College of Osteopathic Medicine. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object ua:8709 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric LightSpeed VCT 64-slice CT
Device facility
Stony Brook University Medical Center (Stony Brook University)
Creator
Groenke, Joseph
Event date
April 24, 2012
Software
GE 07MW18.4
Description
--
Description attachment
None
Reference attachment
None
Exposure time
1825
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
140
Power
--
Amperage
250
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
512
Detector pixels size X
0.248047
Detector pixels Y
512
Detector pixels size Y
0.248047
Detector configuration
Slot (scanned slot, slit, or spot)
Source object distance
541
Source detector distance
949.075012
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
Spiral

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000515752: Quadrate [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Groenke, Joseph
Event date
March 31, 2023
Software
Avizo
Description
cropping and output as dicoms to replace field number(s) with museum accession number
Description attachment
None

Media produced by this event on MorphoSource

Media 000515752: Quadrate [CTImageSeries] [CT] (this media)