Media 000541642: Head
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000541642
Media type
Volumetric Image Series
Object element or part
Head
Object represented
Object taxonomy
Odondebuenia balearica
Object organization
Side
NotApplicable
Orientation
--
Short description
microCT volume and derivatives
Full description
Record created by batch submission.
Creator
Zach Randall
Date created
--
Date uploaded
July 13, 2023

FILE OBJECT DETAILS Field Definitions

File name
USNM_Fish_48411_Head.zip
File format(s)
ZIP archive, TIFF
File size
1.73 GB
Image width
640
Image height
1162
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.007328
Y pixel spacing
0.007328
Z pixel spacing
0.007328
Pixel spacing units
Mm
Slice thickness
0.00732841
Number of images in set
1,699

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Smithsonian Institution, National Museum of Natural History
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object USNM:FISH:USNM 48411 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Zach Randall
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
250.097
Flux normalization
no
Pixel spacing calibration
--
Shading correction
no
Frame averaging
3
Projections
2160
Voltage
80
Power
0.016
Amperage
200
Surrounding material
air
X-ray tube type
--
Target type
Reflection
Detector type
Scintillator (Phosphor used)
Detector pixels X
2024
Detector pixels size X
0.2
Detector pixels Y
2024
Detector pixels size Y
0.2
Detector configuration
Area (single or tiled detector)
Source object distance
29.21565326
Source detector distance
797.32613998
Target material
tungston
Rotation number
--
Phase contrast
no
Optical magnification
no
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000541642: Head [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Zach Randall
Event date
--
Software
DatosX|R
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000541642: Head [CTImageSeries] [CT] (this media)