Media 000549913: Whole Body
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000549913: Whole Body
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
TAGS
GENERAL DETAILS Field Definitions
Media ID
000549913
Media type
Volumetric Image Series
Object element or part
whole body
Object represented
Object taxonomy
Canthigaster cyanospilota
Object organization
Side
--
Orientation
--
Short description
--
Full description
Canthigaster cyanospilota whole body
Creator
Emily Troyer
Date created
August 12, 2021
Date uploaded
August 17, 2023
FILE OBJECT DETAILS Field Definitions
File name
Image_Stack.zip
File format(s)
ZIP archive, JPEG
File size
36.7 MB
Image width
375
Image height
440
Color space
YCbCr
Color depth
8
Compression
JPEG
X pixel spacing
0.071000
Y pixel spacing
0.071000
Z pixel spacing
0.071000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,307
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(1 step)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173, Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Academy of Natural Sciences of Drexel University
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
ANSP:FISH:99949
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)
Creator
Emily Troyer
Event date
August 12, 2021
Software
--
Description
Whole body scan Canthigaster cyanospilota
Description attachment
None
Reference attachment
Exposure time
1700
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
50 kV
Power
--
Amperage
145 uA
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
with 1 activity
to create
derived
Media 000549913: Whole Body [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Processing Activity 1: Reconstruction
Software
NRecon
Description
Media produced by this event on MorphoSource
Media 000549913: Whole Body [CTImageSeries] [CT] (this media)