Media 000692788: Mandible With Dental Plates
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

No collections found.

GENERAL DETAILS Field Definitions

Media ID
000692788
Media type
Volumetric Image Series
Object element or part
Mandible with dental plates
Object represented
Object taxonomy
Dipnorhynchus cathlesae
Side
--
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
November 26, 2021
Date uploaded
December 10, 2024

FILE OBJECT DETAILS Field Definitions

File name
Image_stack_8bit.zip
File format(s)
ZIP archive, TIFF
File size
2.55 GB
Image width
1742
Image height
1742
Color space
BlackIsZero
Color depth
8
Compression
--
X pixel spacing
0.096685
Y pixel spacing
0.096685
Z pixel spacing
0.096685
Pixel spacing units
Millimeters
Slice thickness
--
Number of images in set
2,077

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (2 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Custom Make µCT Scanner Assembled In-House, National Laboratory for X-ray Micro Computed Tomography (Australian National University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Australian National University
Copyright statement
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object anu:60027 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
National Laboratory for X-ray Micro Computed Tomography (Australian National University)
Creator
Levi Beeching
Event date
November 26, 2021
Software
--
Description
CTLab Data Summary ================== General } Sample Type = fossil General } Client = Matt Friedman General } Affiliation = University of Michigan General } Scanned by = levi.beeching@anu.edu.au General } Scan date = 2021-11-26 16:29:53 Specimen details } Number = 60027 Specimen details } Origin place = ANU Collection Specimen details } Shape = complex Experiment details } CTLab Project Name = UMich_Friedman Experiment details } CTLab Sample Name = ANU_Fossils_60027_Dipnorhynchus_cathlesae Experiment details } Micro-CT system name = ANU4 Experiment details } Energy = 220 kV Experiment details } Tube Current = 70 microAmps Experiment details } Target Current = 69.4 microAmps Experiment details } Filter notes = **Empty_No_Data** Experiment details } Filter before sample thickness = 0.95 mm Experiment details } Filter before sample material = stainless steel Experiment details } Filter after sample thickness = **Empty_No_Data** mm Experiment details } Filter after sample material = **Empty_No_Data** Experiment details } Sample distance = 282.999 mm Experiment details } Detector distance = 584.005 mm Reconstructed data details } Voxel size (X=Y=Z) = 0.096684806 mm Reconstructed data details } X and Y Dimensions of volume in pixels = 1742 Reconstructed data details } Z Dimension of volume (number of slices) = 2079 Sample Notes = 1 fossils specimens with two parts packed into plastic sample container ANU#60027 Dipnorynchus cathlesae. Note: third dense fragment scanned separately.
Description Attachment
Photographic Reference
None
Filter
0.95 mm stainless steel
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
2079
Voltage
220 kV
Power
--
Amperage
70 uA
Surrounding material
Plastic container
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
283 mm
Source detector distance
584 mm
Target material
Fossil
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed with 2 activities to create derived Media 000692788: Mandible With Dental Plates [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Processing Activity 1: Reconstruction

Software
Description

Processing Activity 2: Reconstructed Tomography to Mesh

Software
Description

Media produced by this event on MorphoSource

Media 000692788: Mandible With Dental Plates [CTImageSeries] [CT] (this media)