Media 000000559: Calcaneus [CTImageSeries] [Etc]
Represents:
Biological Specimen
In Collection

1 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000000559
Media type
CTImageSeries
File format(s)
image/tiff
File size
194,031,955 bytes
Object element or part
calcaneus
Side
Left
Orientation
--
Short description
Zipped microCT image stack
Full description
Migrated MorphoSource 1 Media File Title: Zipped microCT image stack Migrated MorphoSource 1 Media Group Title: Surface/Smooth Migrated MorphoSource 1 Media File Description: zipped image stack. TIFF format. Migrated MorphoSource 1 Media Group Description: missing tuber scale bar = 5 mm
Creator
--
Date created
--
Date uploaded
August 14, 2013
Image width
538
Image height
376
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.015
Y pixel spacing
0.015
Z pixel spacing
0.015
Pixel spacing units
Mm
Number of images in set
554

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Scanco Medical µCT 40, Stony Brook University Center for Biotechnology (Stony Brook University)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
--
IP holder
Doug Boyer
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
Grant support for this scan: American Association of Physical Anthropology Professional Development Grant to DMB in 2009 National Science Foundation (NSF) grant to D. Boyer and E. Seiffert: BCS 1317525 (formerly BCS 1125507)
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Doug Boyer provided access to these dataoriginally appearing in NSF BCS 1317525. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
--
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object gu:707 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Scanco Medical µCT 40
Device facility
Stony Brook University Center for Biotechnology (Stony Brook University)
Creator
Doug Boyer
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Filter
--
Frame averaging
1
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
none
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000000559: Calcaneus [CTImageSeries] [Etc] (this media).

Processing Details

Creator
Doug Boyer
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000000559: Calcaneus [CTImageSeries] [Etc] (this media)