Media 000039530: Tooth: M3
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000039530
Media type
Volumetric Image Series
Object element or part
tooth: M3
Object represented
Object taxonomy
Conohyus sp.
Side
Right
Orientation
--
Short description
PU/VPL/RS86
Full description
Additional Notes: Found at Sunetar 1, Ramnagar, India. GPS Coordinates given in Gilbert et al. 2014. Referred to Conohyus cf. sindiensis.
Creator
--
Date created
--
Date uploaded
January 17, 2018

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, DICOM
File size
1.12 GB
Image width
910
Image height
845
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.029995
Y pixel spacing
0.029995
Z pixel spacing
0.029995
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
858

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Molecular Imaging Center (University of Southern California)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Biren Patel
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
National Science Foundation (BCS-1945618 to Biren A. Patel; BCS-1945736 to Christopher C. Gilbert)
Publisher
Department of Geology Vertebrate Paleontology Laboratory, Panjab University
Cite as
These data are part of the project "Siwalik Fossils from Ramnagar (Jammu & Kashmir), India" hosted on www.MorphoSource.org (Duke University); the project's curation is funded by the National Science Foundation (BCS-1945618 to Biren A. Patel and BCS-1945736 to Christopher C. Gilbert).
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object pu:vpl:RS86 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Molecular Imaging Center (University of Southern California)
Creator
Biren Patel
Event date
April 09, 2021
Software
--
Description
Inquire with creator
Description attachment
None
Reference attachment
None
Exposure time
1
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
2
Projections
1440
Voltage
120
Power
--
Amperage
130
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000039530: Tooth: M3 [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Biren Patel
Event date
April 09, 2021
Software
--
Description
Inquire with creator
Description attachment
None

Media produced by this event on MorphoSource

Media 000039530: Tooth: M3 [CTImageSeries] [CT] (this media)