Media 000420565: Cranium [Mesh] [CT]
Represents:
Biological Specimen
In Collection
Login or create an account to download files
9 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT
COLLECTIONS MEDIA BELONGS TO
MEDIA TAGS
GENERAL DETAILS
Media ID
000420565
Media type
Mesh
Object element or part
Cranium
Side
NotApplicable
Orientation
--
Short description
--
Full description
--
Creator
Catherine Johnson
Date created
February 09, 2022
Date uploaded
February 09, 2022
FILE OBJECT DETAILS
File format(s)
application/ply
File size
96.3 MB
Points
1,302,140
Polygons
2,604,734
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
15.121, 27.881, 13.795
Centroid coordinates
28.082, 36.032, 11.860
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Computed Tomography in Earth & Environmental Sciences (CTEES) (University of Michigan)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
IP holder
University of Michigan Museum of Zoology (Copyright and License)
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
The European Research Council (ERC) starting grant TEMPO (ERC-2015-STG-677774) to Roger Benson
Publisher
--
Cite as
Serjoscha Evers provided access to these data, originally appearing in "Evers et al. 2022. Independent origin of large labyrinth size in turtles", the collection of which was funded by the European Research Council (ERC) starting grant TEMPO (ERC-2015-STG-677774) to Roger Benson. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
ummz:mammals:156354
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Computed Tomography in Earth & Environmental Sciences (CTEES) (University of Michigan)
Creator
Roger Benson
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
0.25
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
1
Projections
2000
Voltage
110
Power
--
Amperage
135
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000068206: Element Unspecified [CTImageSeries] [Etc]
.
Processing Details
Creator
Roger Benson
Date processed
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000068206: Element Unspecified [CTImageSeries] [Etc]
was processed
to create
derived
Media 000420565: Cranium [Mesh] [CT]
(this media).
Processing Details
Creator
Catherine Johnson
Date processed
--
Software
Avizo
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000420565: Cranium [Mesh] [CT] (this media)