Media 000012770: Skull [Image] [Etc]
Represents:
Biological Specimen
In Collection

1 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

GENERAL DETAILS

Media ID
000012770
Media type
Image
Object element or part
Skull
Side
Midline
Orientation
--
Short description
Skull Preview of Volume Rendering
Full description
Migrated MorphoSource 1 Media File Title: Skull Preview of Volume Rendering Migrated MorphoSource 1 Media Group Title: Zipped Tiff Stack
Creator
--
Date created
--
Date uploaded
May 23, 2016

FILE OBJECT DETAILS

File format(s)
image/jpeg
File size
100 KB
Image width
1069
Image height
762
Color space
YCbCr
Color depth
8/8/8
Compression
JPEG

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS

Data uploaded by
Download permission
Publish with Open Download
Download reviewer
IP holder
Smithsonian Institution, National Museum of Natural History
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
A grant from the LSB Leakey Foundation to LA Gonzales supported scanning and related logisitics. Grants from NSF (BCS 1440742 & 1552848) to DM Boyer supported the processing and upload of these files to MorphoSource.
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Lauren Gonzales provided access to these dataoriginally appearing in , the collection of which was funded by LSB Leakey Foundation. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
--
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object usnm:mammals:439101 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Lauren Gonzales, Darbi Griffith
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
1
Projections
1500
Voltage
159
Power
0.013515000000000001
Amperage
85
Surrounding material
air
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000010596: Skull [CTImageSeries] [Etc] .

Processing Details

Creator
Lauren Gonzales, Darbi Griffith
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000010596: Skull [CTImageSeries] [Etc] was processed to create derived Media 000012770: Skull [Image] [Etc] (this media).

Processing Details

Creator
Lauren Gonzales, Darbi Griffith
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000012770: Skull [Image] [Etc] (this media)