Media 000013337: Petrosal [CTImageSeries] [Etc]
Represents:
Biological Specimen
In Collection

1 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000013337
Media type
CTImageSeries
File format(s)
image/tiff
File size
712,396,364 bytes
Object element or part
petrosal
Side
Left
Orientation
--
Short description
zipped tiff stack
Full description
Migrated MorphoSource 1 Media File Title: zipped tiff stack Migrated MorphoSource 1 Media Group Title: microCT data of petrosal Migrated MorphoSource 1 Media File Description: reversed chirality Migrated MorphoSource 1 Media Group Description: Copyright to this image or model is retained by the UCMNH. This image/model is intended for personal, educational and scientific use only, and may not be published, redistributed, reproduced, or modified and may not be used for commercial or income producing purposes, without UCM's prior written consent. For more information contact: toni.culver@colorado.edu. Or "request download" to engage in a discussion with Culver.
Creator
--
Date created
--
Date uploaded
June 02, 2016
Image width
614
Image height
728
Color space
BlackIsZero
Color depth
16
Compression
--
X pixel spacing
0.00857026
Y pixel spacing
0.00857026
Z pixel spacing
0.00857026
Pixel spacing units
Mm
Number of images in set
1,287

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Share Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
IP holder
University of Colorado Museum of Natural History
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF BCS 1440742 & 1558555 (to DM Boyer and GF Gunnell), BCS 1440588 (to JI Bloch), and BCS 1552848 (to DM Boyer)
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Doug Boyer provided access to these dataoriginally appearing in , the collection of which was funded by NSF BCS 1440742, 1558555, 1552848, & 1440588. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
--
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object ucm:vertebrate:57460 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Share Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Callie Crawford, Doug Boyer
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Filter
--
Frame averaging
1
Projections
1800
Voltage
125
Power
--
Amperage
99
Surrounding material
air
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000013337: Petrosal [CTImageSeries] [Etc] (this media).

Processing Details

Creator
Callie Crawford, Doug Boyer
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000013337: Petrosal [CTImageSeries] [Etc] (this media)