Media 000021474: Ulna [Mesh] [Etc]
Represents:
Biological Specimen
In Collection

GENERAL DETAILS

Media ID
000021474
Media type
Mesh
Object element or part
Ulna
Side
--
Orientation
--
Short description
Smooth Surface Mesh
Full description
Migrated MorphoSource 1 Media File Title: Smooth Surface Mesh Migrated MorphoSource 1 Media Group Title: Zipped Tiff Stack
Creator
--
Date created
--
Date uploaded
January 23, 2017

FILE OBJECT DETAILS

File format(s)
application/ply
File size
18.2 MB
Points
257,702
Polygons
515,400
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
7.029, 17.728, 66.507
Centroid coordinates
11.342, 36.347, 121.714
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS

Data uploaded by
Download permission
Publish with Open Download
IP holder
Duke Lemur Center
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF BCS 1540421
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: The Duke Lemur Center provided access to these data, originally appearing in Yapuncich et al. (2019), the collection of which was funded by NSF BCS 1540421 to Gabriel S. Yapuncich and Doug M. Boyer. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
--
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object dlc:1992m was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Gabriel Yapuncich, Darbi Griffith
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
1
Projections
2000
Voltage
155
Power
0.018600000000000002
Amperage
120
Surrounding material
Air
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000016396: Full Body [CTImageSeries] [Etc] .

Processing Details

Creator
Gabriel Yapuncich, Darbi Griffith
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000016396: Full Body [CTImageSeries] [Etc] was processed to create derived Media 000021474: Ulna [Mesh] [Etc] (this media).

Processing Details

Creator
Gabriel Yapuncich, Darbi Griffith
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000021474: Ulna [Mesh] [Etc] (this media)