Media 000362546: Cervical Vertebrae [Image] [CT]
Represents:
Biological Specimen
Not in Collection

Interactive/Embeddable Media Preview is currently unavailable. Please check back later.

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

GENERAL DETAILS

Media ID
000362546
Media type
Image
Object element or part
Cervical vertebrae
Side
--
Orientation
--
Short description
Cervical vertebrae
Full description
This scan includes cervical vertebrae from the axis (C2) to around C6.
Creator
--
Date created
--
Date uploaded
May 05, 2021

FILE OBJECT DETAILS

File format(s)
application/dicom
File size
137 MB
Image width
512
Image height
512
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.157053
Y pixel spacing
0.157053
Pixel spacing units
Mm
Slice thickness
0.157053
Number of images in set
544

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Animage Fidex CT, Keck XROMM Core Facility (Brown University)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
IP holder
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
We thank the Keck XROMM Core Facility (Brown University) for their donation of scanning time.
Publisher
3D Anatomy Studios
Cite as
3D Anatomy Studios (2021). CT scan of a domestic cat (Felis catus) purchased from Carolina Biological Supply, ID 3DAS-ID00001 (published dicom files). Retrieved from Morphosource ARK: [Insert ARK link].
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object 3DAS:00001 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Animage Fidex CT
Device facility
Keck XROMM Core Facility (Brown University)
Creator
3D Anatomy Studios
Date
February 26, 2021
Software
Animage Fidex
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
745
Voltage
110
Power
--
Amperage
0.1
Surrounding material
Air
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000362546: Cervical Vertebrae [Image] [CT] (this media).

Processing Details

Creator
3D Anatomy Studios
Date processed
February 26, 2021
Software
Animage Fidex
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000362546: Cervical Vertebrae [Image] [CT] (this media)