Media 000697354: Bony Labyrinth
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000697354
Media type
Mesh
Object element or part
Bony Labyrinth
Object represented
Object taxonomy
Poebrotherium eximium
Side
Left
Orientation
--
Short description
--
Full description
--
Creator
Selina Viktor Robson
Date created
December 19, 2024
Date uploaded
December 19, 2024

FILE OBJECT DETAILS Field Definitions

File name
Poebrotherium_eximium_AMNH_FM_47077_BL_L.ply
File format(s)
PLY
File size
73.2 MB
Points
2466391
Polygons
756918
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
37.387, 25.516, 21.057
Centroid coordinates
38.353, 45.340, 20.974 (Bounding Box)
Units of point coordinates
No Value Entered, Millimeter Default

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (1 step)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173, Laboratory of Jason Anderson (University of Calgary)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
American Museum of Natural History
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Prohibited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object amnh:fm:47077 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
Laboratory of Jason Anderson (University of Calgary)
Creator
Selina Viktor Robson
Event date
--
Software
Version 1. 6 (build 24)
Description
--
Description Attachment
None
Photographic Reference
None
Filter
--
Exposure time
2500 ms
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
1800
Voltage
120 kV
Power
--
Amperage
66 uA
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
260.450 mm
Source detector distance
356 mm
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
Sequenced

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed with 1 activity to create derived Media 000694375: Cranium [CTImageSeries] [CT].

Processing Details Field Definitions

Creator
Selina Viktor Robson
Event date
--
Software
ImageJ
Description
--
Description attachment
None

Processing Activity 1: Transform: Reflection

Software
ImageJ
Description
Reflected on horizontal access to correct for mirroring

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000694375: Cranium [CTImageSeries] [CT] was processed to create derived Media 000697354: Bony Labyrinth [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Selina Viktor Robson
Event date
--
Software
3D Slicer
Description
Volumize image stack
Description attachment
None

Media produced by this event on MorphoSource

Media 000697354: Bony Labyrinth [Mesh] [CT] (this media)