Media 000083323: Jaw Fragment Lower [Mesh] [Etc]
Represents:
Biological Specimen
In Collection

1 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

GENERAL DETAILS

Media ID
000083323
Media type
Mesh
Object element or part
jaw fragment lower
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: tif stack, specimen photo, mesh file Migrated MorphoSource 1 Media File Description: mesh file
Creator
--
Date created
--
Date uploaded
July 17, 2019

FILE OBJECT DETAILS

File format(s)
application/ply
File size
27.3 MB
Points
382,386
Polygons
764,632
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
22.647, 16.134, 7.015
Centroid coordinates
50.947, 40.833, 36.186
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS

Download permission
Publish with Restricted Download
IP holder
Duke Lemur Center
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object dpc:24180 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Hesham Sallam
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000082083: Jaw Fragment Lower [CTImageSeries] [Etc] .

Processing Details

Creator
Hesham Sallam
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000082083: Jaw Fragment Lower [CTImageSeries] [Etc] was processed to create derived Media 000083323: Jaw Fragment Lower [Mesh] [Etc] (this media).

Processing Details

Creator
Hesham Sallam
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000083323: Jaw Fragment Lower [Mesh] [Etc] (this media)