Media 000098349: Skeleton / Whole Body [CTImageSeries] [Etc]
Represents:
Biological Specimen
In Collection

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000098349
Media type
CTImageSeries
File format(s)
image/tiff
File size
8,379,293,172 bytes
Object element or part
skeleton / whole body
Side
--
Orientation
--
Short description
zipped 16 bit tiff stack
Full description
Migrated MorphoSource 1 Media File Title: zipped 16 bit tiff stack Migrated MorphoSource 1 Media Group Title: microCT volume and derivatives Migrated MorphoSource 1 Media Group Description: Al calibration
Creator
--
Date created
--
Date uploaded
January 07, 2020
Image width
2240
Image height
2240
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.0295599
Y pixel spacing
0.0295599
Z pixel spacing
0.0295599
Pixel spacing units
Mm
Number of images in set
3,177

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173, Museum of Comparative Zoology (Harvard University)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
IP holder
Yale Peabody Museum
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF DBI-1702263; NSF DBI-1701714; NSF DBI-1701769; overt TCN
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object ypm:vz:ypm herr 006174 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173
Device facility
Museum of Comparative Zoology (Harvard University)
Creator
Matt Gage
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
1.085
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Filter
--
Frame averaging
3
Projections
800
Voltage
50
Power
0.008
Amperage
150
Surrounding material
air
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000098349: Skeleton / Whole Body [CTImageSeries] [Etc] (this media).

Processing Details

Creator
Matt Gage
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000098349: Skeleton / Whole Body [CTImageSeries] [Etc] (this media)