Media 000123963: Head [CTImageSeries] [Etc]
Represents:
Biological Specimen
In Collection

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000123963
Media type
CTImageSeries
File format(s)
image/tiff
File size
2,929,656,136 bytes
Object element or part
head
Side
--
Orientation
--
Short description
zipped tiff stack
Full description
Migrated MorphoSource 1 Media File Title: zipped tiff stack Migrated MorphoSource 1 Media Group Title: microCT volume and derivatives
Creator
--
Date created
--
Date uploaded
July 07, 2020
Image width
790
Image height
1124
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.0151477
Y pixel spacing
0.0151477
Z pixel spacing
0.0151477
Pixel spacing units
Mm
Number of images in set
1,873

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS

Data managed by
Download permission
Publish with Restricted Download
Download reviewer
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
IP holder(s) (Name, Type)
Yale University
Funding attribution
NSF DBI-1701769; oVert TCN; NSF DBI-1701714
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Yale University provided access to these data , the collection of which was funded by oVert TCN. The files were downloaded from www.MorphoSource.org, Duke University.
Additial usage agreement
None
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object ypm:vz:ypm ich 007697 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Zachary Randall
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
0.2
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Filter
--
Frame averaging
3
Projections
1680
Voltage
60
Power
0.012
Amperage
200
Surrounding material
None
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000123963: Head [CTImageSeries] [Etc] (this media).

Processing Details

Creator
Zachary Randall
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000123963: Head [CTImageSeries] [Etc] (this media)