Media 000000850: Dentary [Mesh] [Etc]
Represents:
Biological Specimen
In Collection
Login or create an account to download files
2 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT
COLLECTIONS MEDIA BELONGS TO
MEDIA TAGS
GENERAL DETAILS
Media ID
000000850
Media type
Mesh
Object element or part
dentary
Side
Left
Orientation
--
Short description
Raw Surface file
Full description
Migrated MorphoSource 1 Media File Title: Raw Surface file Migrated MorphoSource 1 Media Group Title: Raw Surface file Migrated MorphoSource 1 Media File Description: Raw surface. Migrated MorphoSource 1 Media Group Description: Raw surface.
Creator
--
Date created
--
Date uploaded
September 10, 2013
FILE OBJECT DETAILS
File format(s)
application/ply
File size
347 MB
Points
4,488,310
Polygons
8,976,582
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
13.764, 8.393, 26.295
Centroid coordinates
13.052, 14.429, 17.482
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
IP holder
University of California Museum of Paleontology; University of California Regents
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
originally appearing in
Media preview mode
--
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
ucmp:v:39205
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Doug Boyer
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
1
Projections
3142
Voltage
155
Power
--
Amperage
150
Surrounding material
none
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000001879: Dentary [CTImageSeries] [Etc]
.
Processing Details
Creator
Doug Boyer
Date processed
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000001879: Dentary [CTImageSeries] [Etc]
was processed
to create
derived
Media 000000850: Dentary [Mesh] [Etc]
(this media).
Processing Details
Creator
Doug Boyer
Date processed
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000000850: Dentary [Mesh] [Etc] (this media)