Media 000004521: Astragalus [Mesh] [Etc]
Represents:
Biological Specimen
In Collection

GENERAL DETAILS

Media ID
000004521
Media type
Mesh
Object element or part
Astragalus
Side
Right
Orientation
--
Short description
Raw Surface Mesh
Full description
Migrated MorphoSource 1 Media File Title: Raw Surface Mesh Migrated MorphoSource 1 Media Group Title: Zipped Tiff Stack
Creator
--
Date created
--
Date uploaded
January 28, 2015

FILE OBJECT DETAILS

File format(s)
application/ply
File size
56.1 MB
Points
842,664
Polygons
1,685,340
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
3.018, 3.084, 1.674
Centroid coordinates
1.658, 1.807, 1.009
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Scanco Medical µCT 35, Yale Core Center for Musculoskeletal Disorder (Yale University)

OWNERSHIP AND PERMISSIONS

Data uploaded by
Download permission
Publish with Open Download
IP holder
University of California Museum of Paleontology; University of California Regents
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF SBE-1028505 (to E.J. Sargis and S.G.B.Chester), the Leakey Foundation (S.G.B. Chester), and a Brooklyn College Tow Faculty Travel Fellowship (S.G.B. Chester), NSF SBR-9616194 (to G.F. Gunnell, P.D. Gingerich, and J.I. Bloch), Yale Institute for Biospheric Studies (to J.I. Bloch), NSF BCS 1317525 (to E. Seiffert and D.M. Boyer); NSF EAR 9505847 (to W.A. Clemens)
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Doug M. Boyer provided access to these dataoriginally appearing in Chester et al. (2015) various sponsors (see Grant support on Morphosource page). The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
--
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object ucmp:v:197486 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Scanco Medical µCT 35
Device facility
Yale Core Center for Musculoskeletal Disorder (Yale University)
Creator
Doug Boyer, Ksenia Sokolova
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000004520: Astragalus [CTImageSeries] [Etc] .

Processing Details

Creator
Doug Boyer, Ksenia Sokolova
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000004520: Astragalus [CTImageSeries] [Etc] was processed to create derived Media 000004521: Astragalus [Mesh] [Etc] (this media).

Processing Details

Creator
Doug Boyer, Ksenia Sokolova
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000004521: Astragalus [Mesh] [Etc] (this media)