Media 000005749: Cranium [Mesh] [Etc]
Represents:
Biological Specimen
In Collection

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000005749
Media type
Mesh
File format(s)
application/ply
File size
116,511,331 bytes
Object element or part
cranium
Side
Midline
Orientation
--
Short description
mesh file
Full description
Migrated MorphoSource 1 Media File Title: mesh file Migrated MorphoSource 1 Media Group Title: surface mesh
Creator
--
Date created
--
Date uploaded
May 27, 2015
Points
1,542,696
Polygons
2,924,348
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
251.139, 177.016, 164.712
Centroid coordinates
95.1, 74.087, 116.698
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Share Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS

Data managed by
Download permission
Publish with Restricted Download
Download reviewer
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
IP holder(s) (Name, Type)
Duke SMIF
Funding attribution
--
Publisher
--
Cite as
originally appearing in
Additial usage agreement
None
Media preview mode
--

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object du:ea:CCC08 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Share Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Doug Boyer
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Filter
--
Frame averaging
1
Projections
1800
Voltage
180
Power
0.03
Amperage
165
Surrounding material
air
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000005749: Cranium [Mesh] [Etc] (this media).

Processing Details

Creator
Doug Boyer
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000005749: Cranium [Mesh] [Etc] (this media)