Media 000036094: 16 Bit Tiffs [CTImageSeries] [Etc]
Represents:
Biological Specimen
In Collection

FILE OBJECT DETAILS

Media ID
000036094
Media type
CTImageSeries
File format(s)
image/tiff
File size
5,493,579,139 bytes
Object element or part
16 bit tiffs
Side
--
Orientation
--
Short description
STL of jaw
Full description
Migrated MorphoSource 1 Media File Title: STL of jaw Migrated MorphoSource 1 Media Group Title: CT scan of UF126295, Lyriocephalus scutatus
Creator
--
Date created
--
Date uploaded
November 04, 2017
Image width
1521
Image height
1158
Color space
BlackIsZero
Color depth
16
Compression
PackBits
X pixel spacing
0.0213969
Y pixel spacing
0.0213969
Z pixel spacing
0.0213969
Pixel spacing units
Mm
Number of images in set
2,022

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS

Data managed by
Download permission
Publish with Restricted Download
Download reviewer
IP holder(s) (Name, Type)
Florida Museum of Natural History
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
oVert Thematic Collections Network (TCN), NSF DBI-1701714
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Additial usage agreement
None
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object uf:herp:126295 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Ed Stanley
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
0.2
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Filter
--
Frame averaging
3
Projections
2200
Voltage
100
Power
0.02
Amperage
200
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000036094: 16 Bit Tiffs [CTImageSeries] [Etc] (this media).

Processing Details

Creator
Ed Stanley
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000036094: 16 Bit Tiffs [CTImageSeries] [Etc] (this media)