Media 000039962: Skeleton [Mesh] [Etc]
Represents:
Biological Specimen
In Collection
Login or create an account to download files
2 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT
COLLECTIONS MEDIA BELONGS TO
MEDIA TAGS
GENERAL DETAILS
Media ID
000039962
Media type
Mesh
Object element or part
Skeleton
Side
--
Orientation
--
Short description
STL of skeletom
Full description
Migrated MorphoSource 1 Media File Title: STL of skeletom Migrated MorphoSource 1 Media Group Title: CT scan of NCSM-herp-34290, Clemmys guttata
Creator
--
Date created
--
Date uploaded
January 26, 2018
FILE OBJECT DETAILS
File format(s)
application/stl
File size
145 MB
Points
1,465,330
Polygons
3,037,084
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
72.578, 59.896, 129.078
Centroid coordinates
-1.179, -4.243, 3.895
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
IP holder
Florida Museum of Natural History
Copyright statement
--
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
oVert Thematic Collections Network (TCN), NSF DBI-1701714
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
ncsm:herp:34290
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
0.2
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
1500
Voltage
100
Power
0.02
Amperage
200
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000039875: 16bit Tiffs [CTImageSeries] [Etc]
.
Processing Details
Creator
Edward Stanley
Date processed
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000039875: 16bit Tiffs [CTImageSeries] [Etc]
was processed
to create
derived
Media 000039962: Skeleton [Mesh] [Etc]
(this media).
Processing Details
Creator
Edward Stanley
Date processed
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000039962: Skeleton [Mesh] [Etc] (this media)