Media 000052987: 16 Bit Tiff [CTImageSeries] [Etc]
Represents:
Biological Specimen
In Collection

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000052987
Media type
CTImageSeries
File format(s)
image/tiff
File size
55,779,105 bytes
Object element or part
16-bit TIFF
Side
--
Orientation
--
Short description
Z-Stack
Full description
Migrated MorphoSource 1 Media File Title: Z-Stack Migrated MorphoSource 1 Media Group Title: CT scan of fmnh-amphibians and reptiles-83533, Ablepharus pannonicus Migrated MorphoSource 1 Media Group Description: fluid-preserved specimen
Creator
--
Date created
--
Date uploaded
July 01, 2018
Image width
711
Image height
310
Color space
BlackIsZero
Color depth
16
Compression
PackBits
X pixel spacing
0.029215
Y pixel spacing
0.029215
Z pixel spacing
0.029215
Pixel spacing units
Mm
Number of images in set
1,876

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s, UChicago PaleoCT (University of Chicago)

OWNERSHIP AND PERMISSIONS

Data managed by
Download permission
Publish with Restricted Download
Download reviewer
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
IP holder(s) (Name, Type)
Field Museum of Natural History
Funding attribution
NSF DBI-1701714; NSF DBI-1702421; oVert TCN
Publisher
--
Cite as
originally appearing in , the collection of which was funded by oVert TCN
Additial usage agreement
None
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object fmnh:amphibians and reptiles:83533 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s
Device facility
UChicago PaleoCT (University of Chicago)
Creator
Stephanie Baumgart
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
0.2
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Filter
--
Frame averaging
3
Projections
800
Voltage
80
Power
0.011
Amperage
140
Surrounding material
air
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000052987: 16 Bit Tiff [CTImageSeries] [Etc] (this media).

Processing Details

Creator
Stephanie Baumgart
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000052987: 16 Bit Tiff [CTImageSeries] [Etc] (this media)