Media 000065103: Element Unspecified [CTImageSeries] [Etc]
Represents:
Biological Specimen
In Collection

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000065103
Media type
CTImageSeries
File format(s)
image/tiff
File size
416,110,127 bytes
Object element or part
--
Side
--
Orientation
--
Short description
zipped tiff stack
Full description
Migrated MorphoSource 1 Media File Title: zipped tiff stack Migrated MorphoSource 1 Media Group Title: microCT volume and derivatives
Creator
--
Date created
--
Date uploaded
December 05, 2018
Image width
1365
Image height
909
Color space
BlackIsZero
Color depth
16
Compression
PackBits
X pixel spacing
0.0679178
Y pixel spacing
0.0679178
Z pixel spacing
0.0679178
Pixel spacing units
Mm
Number of images in set
2,413

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s, UChicago PaleoCT (University of Chicago)

OWNERSHIP AND PERMISSIONS

Data managed by
Download permission
Publish with Restricted Download
Download reviewer
--
IP holder(s) (Name, Type)
Field Museum of Natural History
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF DBI-1702421; NSF DBI-1701714; oVert TCN
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Field Museum of Natural History provided access to these data provided access to these data , the collection of which was funded by oVert TCN. The files were downloaded from www.MorphoSource.org, Duke University.
Additial usage agreement
None
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object fmnh:amphibians and reptiles:68188 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s
Device facility
UChicago PaleoCT (University of Chicago)
Creator
Stephanie Baumgart
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
0.25
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Filter
--
Frame averaging
3
Projections
1500
Voltage
150
Power
0.038
Amperage
250
Surrounding material
Air
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000065103: Element Unspecified [CTImageSeries] [Etc] (this media).

Processing Details

Creator
Stephanie Baumgart
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource