Media 000065728: Whole Body [Mesh] [Etc]
Represents:
Biological Specimen
In Collection

FILE OBJECT DETAILS

Media ID
000065728
Media type
Mesh
File format(s)
application/stl
File size
105,607,784 bytes
Object element or part
whole body
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: microCT volume and derivatives
Creator
--
Date created
--
Date uploaded
December 19, 2018
Points
1,044,925
Polygons
2,110,773
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
65.525, 49.505, 81.896
Centroid coordinates
-8.968, -9.297, 2.777
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS

Data managed by
Download permission
Publish with Restricted Download
Download reviewer
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
IP holder(s) (Name, Type)
Florida Museum of Natural History
Funding attribution
NSF DBI-1701714; oVert TCN
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: University of Florida provided access to these data provided access to these data , the collection of which was funded by oVert TCN. The files were downloaded from www.MorphoSource.org, Duke University.
Additial usage agreement
None
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object uf:herp:87142 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
0.2
Flux normalization
Yes
Pixel spacing calibration
--
Shading correction
Yes
Filter
--
Frame averaging
3
Projections
1600
Voltage
100
Power
0.02
Amperage
200
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000065727: Whole Body [CTImageSeries] [Etc] .

Processing Details

Creator
Edward Stanley
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000065727: Whole Body [CTImageSeries] [Etc] was processed to create derived Media 000065728: Whole Body [Mesh] [Etc] (this media).

Processing Details

Creator
Edward Stanley
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000065728: Whole Body [Mesh] [Etc] (this media)