Media 000078624: Whole Body [CTImageSeries] [Etc]
Represents:
Biological Specimen
In Collection
Login or create an account to download files
0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT
COLLECTIONS MEDIA BELONGS TO
MEDIA TAGS
GENERAL DETAILS
Media ID
000078624
Media type
CTImageSeries
Object element or part
whole body
Side
--
Orientation
--
Short description
zipped tiff stack
Full description
Migrated MorphoSource 1 Media File Title: zipped tiff stack Migrated MorphoSource 1 Media Group Title: microCT volume and derivatives
Creator
--
Date created
--
Date uploaded
May 23, 2019
FILE OBJECT DETAILS
File format(s)
image/tiff
File size
201 MB
Image width
774
Image height
874
Color space
BlackIsZero
Color depth
16
Compression
PackBits
X pixel spacing
0.010414
Y pixel spacing
0.010414
Z pixel spacing
0.010414
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
3,187
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
IP holder
College of William & Mary Virginia Institute of Marine Science
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF DBI-1701714; NSF DBI-1702143; oVert TCN
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: College of William & Mary Virginia Institute of Marine Science provided access to these data , the collection of which was funded by oVert TCN. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
vims:fish:33455
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Zachary Randall
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
0.333096
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
3
Projections
1080
Voltage
60
Power
0.009
Amperage
150
Surrounding material
None
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000078624: Whole Body [CTImageSeries] [Etc]
(this media).
Processing Details
Creator
Zachary Randall
Date processed
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000078624: Whole Body [CTImageSeries] [Etc] (this media)