Media 000100273: Skull
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
ยท Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000100273
Media type
Volumetric Image Series
Object element or part
skull
Object represented
Object taxonomy
Vulpes lagopus lagopus
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: HRXCT scan Migrated MorphoSource 1 Media File Description: University of Texas High-Resolution X-ray CT Facility Archive 0117 \\r\\n\\r\\nScanned images of skulls and turbinates of alopex lagopus innuitus (arctic fox) for Blaire Van Valkenburg and Ari Pollack of UCLA. Scanning done by Richard Ketcham on 7/22-7/26/99. Samples mounted in plexiglass cylinders, held in place with foam. Only 16-bit TIFF image files archived.\\r\\n\\r\\nAlopex/male: Collection of Donald R. Dickey, specimen #15,161, from Barrow, Alaska.\\r\\nSkull: II, 120 kV, 0.120 mA, no filter, air wedge, no offset, slice thickness 1.129 mm, S.O.D. 280 mm, 1200 views, 2 samples per view, inter-slice spacing 1.129 mm, field of reconstruction 80 mm, reconstruction offset 400, reconstruction scale 155. Scanned in 3-slice mode.
Creator
--
Date created
--
Date uploaded
February 04, 2020

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
18.3 MB
Image width
498
Image height
406
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.156300
Y pixel spacing
0.156300
Z pixel spacing
1.129000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
121

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
University of California Los Angeles
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
IIS-9874781, DBI-1902242
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Blaire Van Valkenburgh and Tim Rowe provided access to these data , with data collection funded by NSF IIS-9874781 and data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UCLA:Mammals:15161 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Richard Ketcham
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
2
Projections
1200
Voltage
120
Power
--
Amperage
120
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000100273: Skull [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Richard Ketcham
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000100273: Skull [CTImageSeries] [Etc] (this media)