Media 000159623: Mandible
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)

Media Display

In Collections

Team
· Public
Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000159623
Media type
Volumetric Image Series
Object element or part
mandible
Object represented
Object taxonomy
Trachypithecus phayrei crepusculus
Object organization
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: HRXCT scan Migrated MorphoSource 1 Media File Description: University of Texas High-Resolution X-ray CT Facility Archive D1\\r\\n\\r\\nCoiner-Collier:\\r\\nUSNM307736_: Scans of the mandible of Trachypithecus phayrei crepusculus (USNM 307736, Thailand) for Susan Coiner-Collier of Rutgers University. Specimen scanned by Matthew Colbert 12 September 2014. \\r\\n\\r\\n16bit: Scan parameters: NSI scanner. Feinfocus source, high power, 150 kV, 0.24 mA, no filter, Perkin Elmer detector, 0.5 pF gain, 5 fps (199.982 ms integration time), 2x2 binning, no flip, source to object 241 mm, source to detector 1064 mm, continuous CT scan, no frames averaged, 0 skip frames, 8000 projections, 7 gain calibrations, 5 mm calibration phantom, data range [-10, 250] (rescaled from NSI default), beam-hardening correction = 0.3. Voxel size = 0.0993 mm. Total slices = 661.\\r\\n
Creator
--
Date created
--
Date uploaded
September 20, 2020

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
271 MB
Image width
672
Image height
455
Color space
BlackIsZero
Color depth
16
Compression
--
X pixel spacing
0.099300
Y pixel spacing
0.099300
Z pixel spacing
0.099300
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
661

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging NSI Custom build, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
IP holder
Smithsonian Institution, National Museum of Natural History
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
DBI-1902242
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Susan Coiner-Collier and Robert Scott provided access to these data , with data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object USNM:MAMM:USNM 307736 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging NSI Custom build
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.2
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
none
Projections
8000
Voltage
150
Power
--
Amperage
240
Surrounding material
0.5 pF gain
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000159623: Mandible [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000159623: Mandible [CTImageSeries] [Etc] (this media)