Media 000508269: Pelvis
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000508269
Media type
Mesh
Object element or part
pelvis
Object represented
Object taxonomy
Leporillus apicalis
Side
Midline
Orientation
--
Short description
pelvis of Leporillus apicalis
Full description
Record created by batch submission.
Creator
Taewcharoen, Nuttakorn
Date created
November 06, 2022
Date uploaded
March 28, 2023

FILE OBJECT DETAILS Field Definitions

File name
SAMA_M4074_Leporillus_apicalis_Pelvis_m_CT.stl
File format(s)
STL
File size
164 MB
Points
1716832
Polygons
3434208
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
24.876, 22.278, 39.376
Centroid coordinates
25.029, -56.361, 110.499
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Medical Device Research Institute (Flinders University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
Museum Board of South Australia
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
CABAH
Publisher
Ozboneviz
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object SAMA:Mammalogy:M4074 was imaged to create raw Media 000508195: Whole [CTImageSeries] [CT].

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Medical Device Research Institute (Flinders University)
Creator
Perilli, Egon
Event date
June 28, 2022
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

Media produced by this event on MorphoSource

STEP 2: IMAGE PROCESSING

Raw Media 000508195: Whole [CTImageSeries] [CT] was processed to create derived Media 000508269: Pelvis [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Taewcharoen, Nuttakorn
Event date
November 06, 2022
Software
3D slicer
Description
segmented using threshold tool and manual paint/eraser tool
Description attachment
None

Media produced by this event on MorphoSource

Media 000508269: Pelvis [Mesh] [CT] (this media)