Media 000598005: Periotic
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000598005: Periotic
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000598005
Media type
Mesh
Object element or part
periotic
Object represented
Object taxonomy
Sousa sahulensis
Object organization
Side
Right
Orientation
--
Short description
Right periotic of a Sousa sahulensis
Full description
Donated to Ozboneviz by Toshiyuki Kimura, Gunma Museum of Natural History. See Kimura, T. 2023. 3D digitization of the natural history museum specimens: A case study of building the 3D digital database of the periotic and tympanic bulla of modern cetaceans. Bull. Gunma Mus. Natu. Hist. (27): 211-216.
Creator
Kimura, Toshiyuki
Date created
August 14, 2022
Date uploaded
January 16, 2024
FILE OBJECT DETAILS Field Definitions
File name
Sousa_sahulensis_SAM_M26583_pe_lz.stl
File format(s)
STL
File size
2.32 MB
Points
24289
Polygons
48602
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
23.079, 14.270, 32.113
Centroid coordinates
71.052, 54.559, 35.622
Units of point coordinates
No Value Entered, Millimeter Default
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Siemens Somatom Force, SAHMRI (South Australian Health and Medical Research Institute) (Jones Radiology)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
The Museum Board of South Australia
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
Gunma Museum of Natural History
Publisher
Ozboneviz
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
SAMA:Mammalogy:M26583
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Device facility
SAHMRI (South Australian Health and Medical Research Institute) (Jones Radiology)
Creator
--
Event date
August 14, 2022
Software
--
Description
--
Description Attachment
None
Photographic Reference
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000598005: Periotic [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Toshiyuki, Kimura
Event date
August 14, 2022
Software
Osirix
Description
Segmentation
Description attachment
None